Related Experiment Video
Updated: Dec 7, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
RV Tissue Heterogeneity on CT: A Novel Tool to Identify the VT Substrate in ARVC
Jeroen Venlet1, Qian Tao2, Michiel A de Graaf1
1Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands.
Objectives:
This study sought to evaluate whether right ventricular (RV) tissue heterogeneity on computed tomography (CT): 1) is associated with conduction delay in arrhythmogenic right ventricular cardiomyopathy (ARVC); and 2) distinguishes patients with ARVC from those with exercise-induced arrhythmogenic remodeling (EIAR) and control individuals.
Background:
ARVC is characterized by fibrofatty replacement, related to conduction delay and ventricular tachycardias. Distinguishing ARVC from acquired, EIAR is challenging.
Methods:
Patients with ARVC or EIAR and combined endocardial-epicardial electroanatomic voltage mapping for VT ablation with CT integration were enrolled. Patients without structural heart disease served as control individuals. Tissue heterogeneity on CT (CT heterogeneity) was automatically quantified within the 2-mm subepicardium of the entire RV free wall at normal sites and low voltage sites harboring late potentials (LP+) in ARVC/EIAR.
Results:
Seventeen patients with ARVC (15 males; age: 50 ± 17 years), 9 patients with EIAR (7 males; age: 45 ± 14 years) and 17 control individuals (14 males; age: 50 ± 15 years) were enrolled. Of 5,215 ARVC mapping points, 560 (11%) showed LP+. CT heterogeneity was higher at sites with LP+ compared to normal sites (median: 31 HU/mm; IQR: 23 to 46 HU/mm vs. median: 16 HU/mm; IQR: 13 to 21 HU/mm; p < 0.001). The optimal CT heterogeneity cutoff for detection of LP+ was 25 HU/mm (area under the curve [AUC]: 0.80; sensitivity: 72%; specificity: 78%). Overall CT heterogeneity allowed highly accurate differentiation between patients with ARVC and control individuals (AUC: 0.97; sensitivity: 100%; specificity: 82%) and between ARVC and EIAR (AUC: 0.78; sensitivity: 65%; specificity: 89%).
Conclusions:
In patients with ARVC, tissue heterogeneity on CT can be used to identify LP+ as a surrogate for ventricular tachycardia substrate. The overall tissue heterogeneity on CT allows the distinguishing of patients with ARVC from those with EIAR and control individuals.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...