What is the mechanism of narrow paced QRS duration during left bundle branch area pacing? A case report
Yusuke Hayashi1, Kenji Shimeno1, Kenichi Nakatsuji1
1Department of Cardiology, Osaka City General Hospital, 2-13-22 Miyakojima-hondori, Miyakojima-ku, Osaka 534-0021, Japan.
Background:
Although left bundle branch area pacing (LBBAP) can capture the His-Purkinje conduction system and create a narrower paced QRS duration, its mechanism has not been investigated. In this case report, ventricular activation patterns were evaluated using three-dimensional electroanatomical mapping during LBBAP and right ventricular septal pacing (RVSP).
Case Summary:
An 81-year-old woman with sick sinus syndrome received LBBAP, followed 4 months later with atrial fibrillation ablation. We compared ventricular activation patterns during RVSP and LBBAP using a three-dimensional electro-anatomical mapping system. Paced QRS durations during RVSP and LBBAP were 163 ms and 115 ms, respectively. The activation pattern and the total left ventricular (LV) activation time were similar during RVSP and LBBAP (86 and 73 ms, respectively), despite the conduction system capture during LBBAP. The stimulus interval to the latest LV activation point during RVSP was 117 ms, and transseptal conduction time was 31 ms (117 - 86 ms).
Discussion:
Although LBBAP could capture the His-Purkinje conduction system, neither ventricular activation patterns nor total activation time changed dramatically. The mechanism of narrower paced QRS duration during LBBAP compared to that during RVSP can be attributable to passing over the slow transseptal conduction.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Electrophysiology of Normal Cardiac Rhythm
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias III: Characteristics of Dysrhythmias