Related Experiment Video
Updated: Dec 7, 2025

Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
PulseDIA: Data-Independent Acquisition Mass Spectrometry Using Multi-Injection Pulsed Gas-Phase Fractionation
Xue Cai1,2, Weigang Ge1,2, Xiao Yi1,2
1Zhejiang Provincial Laboratory of Life Sciences and Biomedicine, Key Laboratory of Structural Biology of Zhejiang Province, School of Life Sciences, Westlake University, 18 Shilongshan Road, Hangzhou 310024, Zhejiang, China.
Abstract:
The performance of data-independent acquisition (DIA) mass spectrometry (MS) depends on the separation efficiency of peptide precursors. In Orbitrap-based mass spectrometers, separation efficiency of peptide precursors is limited by the relatively slow scanning rate compared to time of flight (TOF)-based MS. Here, we present PulseDIA, a multi-injection gas-phase fractionation (GPF) strategy for enhanced DIA-MS. This is achieved by equally dividing the conventional DIA analysis covering the entire mass range into multiple injections for DIA analyses with complementary windows. Using mouse liver digests, the PulseDIA method identified up to 50% more peptides and 29% more protein groups than that by conventional DIA with the same length of effective gradient time. Compared to conventional multi-injection GPF, PusleDIA exhibited higher flexibility and identified up to 18% more peptides and 8% more protein groups using two injections. The gain of peptides per effective time unit was the highest in PulseDIA compared to conventional DIA and GPF. We further applied the PulseDIA method to profile the proteome of 18 human tissue samples (benign and malignant) from nine cholangiocarcinoma (CCA) patients. PulseDIA identified 7796 protein groups in these CCA samples, with a 14% increase of protein group identification compared to the conventional DIA method. The missing value for protein matrix dropped by 7% using PulseDIA compared to DIA. A total of 681 significantly altered proteins were detected in CCA samples using PulseDIA, including several dysregulated proteins, which were absent in the conventional DIA analysis. Taken together, we present PulseDIA as an enhanced DIA-MS method with improved sensitivity and reproducibility.
More Related Videos
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometers