Kinematic but not clinical measures predict falls in Parkinson-related orthostatic hypotension
Andrea Sturchio1,2,3, Alok K Dwivedi4, Luca Marsili1
1Department of Neurology, Gardner Family Center for Parkinson's Disease and Movement Disorders, University of Cincinnati, Cincinnati, OH, USA.
Objective:
We sought to test the hypothesis that technology could predict the risk of falls in Parkinson's disease (PD) patients with orthostatic hypotension (OH) with greater accuracy than in-clinic assessment.
Methods:
Twenty-six consecutive PD patients with OH underwent clinical (including home-like assessments of activities of daily living) and kinematic evaluations of balance and gait as well as beat-to-beat blood pressure (BP) monitoring to estimate their association with the risk of falls. Fall frequency was captured by a diary collected prospectively over 6 months. When applicable, the sensitivity, specificity, and diagnostic accuracy were measured using the area under the receiver operating characteristics curve (AUC). Additional in-clinic assessments included the OH Symptom Assessment (OHSA), the OH Daily Activity Score (OHDAS), and the Movement Disorder Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS).
Results:
The prevalence of falls was 53.8% over six months. There was no association between the risk of falls and test of gait and postural stability (p ≥ 0.22) or home-like activities of daily living (p > 0.08). Conversely, kinematic data (waist sway during time-up-and-go, jerkiness, and centroidal frequency during postural sway with eyes-opened) predicted the risk of falls with high sensitivity and specificity (> 80%; AUC ≥ 0.81). There was a trend for higher risk of falls in patients with orthostatic mean arterial pressure ≤ 75 mmHg.
Conclusions:
Kinematic but not clinical measures predicted falls in PD patients with OH. Orthostatic mean arterial pressure ≤ 75 mmHg may represent a hemodynamic threshold below which falls become more prevalent, supporting the aggressive deployment of corrective measures.
More Related Videos
Related Concept Videos
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.