Related Experiment Video
Updated: Dec 7, 2025

Collection of Alfalfa Root Exudates to Study the Impact of Di2-ethylhexyl Phthalate on Metabolite Production
Published on: June 2, 2023
Between- and within-individual variability of urinary phthalate and alternative plasticizer metabolites in spot,
Michiel Bastiaensen1, Govindan Malarvannan1, Celine Gys1
1Toxicological Center, University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Belgium.
Abstract:
Due to international regulations, commonly used phthalates such as di(2-ethylhexyl) phthalate (DEHP) are being replaced by other phthalates, such as di-isononyl phthalate (DINP), and di-isodecyl phthalate (DIDP) and by alternative plasticizers (APs) with similar chemical characteristics, like di(isononyl)cyclohexane-1,2-dicarboxylate (DINCH), di(2-ethylhexyl) terephthalate (DEHTP), or di-(2-ethylhexyl) adipate (DEHA). Urinary concentrations of metabolites are frequently used in the exposure assessment of non-persistent chemicals and for biomonitoring purposes, the intra- and inter-day variability of the metabolites should be known. However, the short-term variability of AP and several phthalate biomarkers has not been investigated yet. In this study, we collected all spot samples from 10 healthy adults for 5 consecutive days and 24h pooled urine on one additional day to investigate the short-term variability of 22 biomarkers of phthalates and APs. Metabolites of DEP, DEHP, DiBP, DnBP, DBzP, DINP and DIDP were found in high detection frequencies, while metabolites of most APs were found in approximately 50% of the samples. The short-term reproducibility of metabolites with diet as primary source (DEHP, DINP, DIDP) was poor (intraclass correlation coefficient - ICC < 0.4), whereas biomarkers of DEP, DnBP, DiBP and BBzP showed good consistency, most likely due to more continuous sources resulting in less between-day variance. ICC values of AP metabolites were similar to those of DEHP, but more studies are required to confirm these findings. Overall, reproducibility improved considerably when values were corrected for urinary dilution and when only morning voids samples were considered. Levels in morning voids samples were consistent for 5 days and comparable to 24-h pooled urine for all metabolites except for OH-MEHTP, sum DINP and sum DIDP, which supports the use of morning voids in human biomonitoring studies.
More Related Videos
05:05Quantification of Polybutylene Adipate Terephthalate-based Micro- and Nano-plastics from Soil Using Proton Nuclear Magnetic Resonance Spectroscopy
Published on: June 6, 2025
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018