Related Experiment Video
Updated: Dec 7, 2025

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report
K H Teh1, J K Ruben2, C K Chan3
1Department of Orthopaedic Surgery, Universiti Putra Malaysia, Serdang, Malaysia.
Abstract:
Avascular necrosis and non-union are two most dreaded complications of femoral neck fracture fixations. Hip replacement seems to be a simple solution for this complex problem. However, the long-term efficacy of prosthetic replacement in the young population with higher functional demand is still questionable. Femoral head preserving valgus subtrochanteric osteotomies in properly selected cases have strong support from literature. The conventional technique of valgus subtrochanteric osteotomy involves lateral based wedge resection. Alternatively, a simpler sliding oblique subtrochanteric osteotomy without any wedge removal can also be performed. We hereby describe a successful case of sliding subtrochanteric osteotomy with 135° dynamic hip screw (DHS) plate fixation in treating non-union neck of femur fracture in a young gentleman.