Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Blood pressure estimation system using human body communication-based electrocardiograph and photoplethysmography
Yusuke Sawatari1, Jianqing Wang1, Daisuke Anzai1
1Nagoya Institute of Technology, Nagoya 466-8555, Japan.
Abstract:
In order to realise low-load cuffless and continuous blood pressure measurement in daily life, the authors developed a blood pressure estimation system combining human body communication-based wearable electrocardiograph and reflectance photoplethysmography. The principle is based on a relationship between the pulse arrive time and the systolic blood pressure. The pulse arrive time is the time period between the R-wave in electrocardiograph and peak of pulse wave. The greatest feature is the use of a human body communication-based electrocardiograph which can provide automatic synchronisation in time between the measured electrocardiograph and pulse wave signals to obtain the pulse arrive time so that no additional synchronisation circuit is required. Using this system, the authors measured the pulse arrive time from the electrocardiograph and pulse wave signals in real time, estimated the systolic blood pressure and compared the result with that measured by a cuff sphygmomanometer. The authors found that the root mean square error of the estimated blood pressure and the actual value measured using the cuff sphygmomanometer was 4.5 mmHg or less, and the correlation coefficient was >0.6 with a P value much <0.05. These results show the validity of the developed system for cuffless and continuous blood pressure estimation.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)