Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

3.0K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.0K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

1.3K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
1.3K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

4.1K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
4.1K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

2.6K
High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
2.6K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

676
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
676
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

924
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
924

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reversible lenticulostriate perforator aneurysms in herpes simplex encephalitis.

Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia·2026
Same author

Quantitative systems toxicology approach that integrates PBPK and core hepatic metabolism: a case study with valproic acid.

Frontiers in pharmacology·2026
Same author

RNF25 confers mRNA damage tolerance by curbing activation of the integrated stress response.

Molecular cell·2026
Same author

Effect of a home-based supervised personalised diet on malnutrition and frailty in dialysis patients: a randomised controlled trial.

BMC nutrition·2026
Same author

Safety and Effectiveness of Insulin Degludec in Patients With Type 2 Diabetes Mellitus With Chronic Liver Disease.

Cureus·2026
Same author

ERCC6L2 ensures repair fidelity for staggered-end DNA double-strand breaks.

Nature communications·2026

Related Experiment Video

Updated: Dec 7, 2025

Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers
10:21

Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers

Published on: May 5, 2016

11.1K

Miniature Multiwavelength Deep UV-LED-Based Absorption Detection System for Capillary LC.

Mohamed Hemida1,2, Lewellwyn Joseph Coates1,2,3, Shing Lam1,2

  • 1ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.

Analytical Chemistry
|September 28, 2020
PubMed
Summary
This summary is machine-generated.

A novel miniature deep ultraviolet (UV) absorbance detector was created using affordable light-emitting diodes (LEDs). This compact detector offers versatile scanning and single-wavelength capabilities for capillary liquid chromatography (LC) systems.

More Related Videos

Visual Detection of Multiple Nucleic Acids in a Capillary Array
08:56

Visual Detection of Multiple Nucleic Acids in a Capillary Array

Published on: November 15, 2017

7.5K
Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
06:50

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb

Published on: December 2, 2017

9.5K

Related Experiment Videos

Last Updated: Dec 7, 2025

Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers
10:21

Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers

Published on: May 5, 2016

11.1K
Visual Detection of Multiple Nucleic Acids in a Capillary Array
08:56

Visual Detection of Multiple Nucleic Acids in a Capillary Array

Published on: November 15, 2017

7.5K
Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
06:50

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb

Published on: December 2, 2017

9.5K

Area of Science:

  • Analytical Chemistry
  • Instrumentation Science

Background:

  • Miniaturization of analytical instruments is crucial for portability and reduced reagent consumption.
  • Deep UV absorbance detection is essential for analyzing various compounds, including pharmaceuticals and biomolecules.

Purpose of the Study:

  • To develop and characterize a cost-effective, miniature deep UV absorbance detector for capillary liquid chromatography (LC).
  • To evaluate the performance of the new detector against a conventional capillary LC detector.

Main Methods:

  • Construction of a detector using off-the-shelf components: light-emitting diodes (LEDs), fiber optics, a capillary Z-type flow cell, and photodiodes.
  • Operation in scanning mode (230–300 nm) and individual wavelength modes (240, 255, 275 nm).
  • Performance characterization including stray light, flow cell path length utilization, dynamic range, and noise levels, with benchmarking against a standard detector.

Main Results:

  • The detector demonstrated very low stray light (<0.4%) and high effective path length utilization (99.0%).
  • A wide dynamic range (0.5–200 μg/mL) was achieved for analytes like sulfamethazine, carbamazepine, and flavone.
  • Low noise levels (300 μAU) were observed, suitable for sensitive capillary LC applications.

Conclusions:

  • The developed miniature deep UV absorbance detector offers a low-cost, high-performance alternative for capillary LC.
  • Its compact design and robust performance make it suitable for miniaturized analytical systems.
  • The detector's capabilities enable sensitive and versatile detection in deep UV range.