A simplified screening method for short- and medium-chain chlorinated paraffins in food by gas chromatography-low
Thomas J McGrath1, Giulia Poma1, Jasper Bombeke1
1Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Belgium.
Abstract:
This study evaluates the performance of a simplified screening method for short- and medium-chain chlorinated paraffins (SCCPs and MCCPs, respectively) based on gas chromatography-electron capture negative ionization/mass spectrometry (GC-ECNI/MS) analysis and chlorine content quantification. The response from different combinations of 'indicator' congener groups present in technical mixture standards were used within calibration calculations to test the hypothesis that ∑SCCPs and ∑MCCPs could be quantified with acceptable accuracy using only a subset of the commonly analysed C10 to C17 and Cl5 to Cl10 groups. Potential combinations were assessed with respect to calibration curve performance and accuracy of SCCP and MCCP analysis of spiked food samples (olive oil, salmon, pork sausage, breakfast cereal, cow's milk and lard). Based on these trials, a screening method which quantifies ∑SCCPs and ∑MCCPs using only congener groups with 6 and 8 chlorine atoms for each carbon chain length was proposed. Concentrations of SCCPs and MCCPs in triplicate analyses of spiked food samples calculated using the proposed screening method deviated by ≤ 25% for the vast majority of samples (maximum deviation 37%) from levels determined using all analysed congener groups. The mean trueness of the screening method as applied to each of the spiked food samples and lard samples from a previous European Union Reference Laboratory (EURL) interlaboratory study ranged from 65 to 110% for ∑SCCPs and 102 to 175% for ∑MCCPs. Relative standard deviations (RSDs) were ≤ 25% for all triplicate analyses and matrix specific LOQs ranged from 0.7 to 6 ng/g ww for ∑SCCPs and from 1.3 to 12 ng/g ww for ∑MCCPs. The proposed screening method has the potential to deliver substantial time savings in instrumental analysis and manual labour without greatly reducing the overall accuracy and sensitivity of SCCP and MCCP quantification.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...