Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
3D UTE bicomponent imaging of cortical bone using a soft-hard composite pulse for excitation
Liang Li1,2, Yanjun Chen2,3, Zhao Wei2
1Department of Radiology, Renmin Hospital of Wuhan University, Wuhan, Hubei, People's Republic of China.
Purpose:
To evaluate 3D UTE bicomponent imaging of cortical bone ex vivo and in vivo using a newly designed soft-hard composite pulse for excitation.
Methods:
Chemical shift artifacts, presenting as fat-water oscillation or combination-induced signal oscillation, significantly reduce the accuracy of quantitative UTE bicomponent analysis of cortical bone. To achieve fat suppression for more reliable bicomponent analysis, a newly developed soft-hard excitation pulse was used with UTE imaging and compared with a single rectangular pulse excitation without and with a conventional fat saturation (FatSat) module. These 3 sequences were applied to 8 bovine bone samples without marrow fat, 3 bovine bone samples with marrow fat, and tibial midshafts of 5 healthy human volunteers. Bicomponent analyses were performed in both ex vivo and in vivo studies.
Results:
The soft-hard pulse provided comparable fat suppression, but much reduced bone signal attenuation compared with the FatSat module. Better bicomponent fitting was also achieved with the soft-hard excitation pulse because it greatly reduced chemical shift artifacts and outperformed the single rectangular pulse without or with FatSat. Although the FatSat module reduced fat signals and related fat-water oscillation, the water signals were significantly attenuated with more than 40% reduction due to direction saturation. For the inner layer of tibial midshaft in healthy volunteers, fitting errors increased from 3.78% for the soft-hard pulse to 11.43% and 5.16%, respectively, for the single rectangular pulse without and with the FatSat module.
Conclusion:
The 3D UTE sequence with a new soft-hard excitation pulse allows more reliable bicomponent imaging of cortical bone.
More Related Videos
07:10A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Ultrasonography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT