ASTEROID stereotest v1.0: lower stereo thresholds using smaller, denser and faster dots
Jenny C A Read1, Zhen Yi Wong1, Xinye Yek1
1Biosciences Institute, Newcastle University, Newcastle upon Tyne, UK.
Summary
The updated ASTEROID v1.0 stereotest, using smaller, denser dots, shows improved stereo thresholds comparable to clinical standards. This version offers better accuracy and repeatability for assessing binocular vision in healthy adults.
Area of Science:
- Ophthalmology
- Vision Science
- Computer-aided diagnostics
Background:
- The initial ASTEROID (v0.9) stereotest, utilizing a 3D tablet, demonstrated good correlation with existing methods but yielded higher stereo thresholds.
- This discrepancy was hypothesized to stem from the large, sparse dots employed in ASTEROID v0.9.
Purpose of the Study:
- To introduce and evaluate the stereo thresholds and test-retest repeatability of the revised ASTEROID v1.0.
- To compare the performance of ASTEROID v1.0 against its predecessor (v0.9) and a standard clinical stereotest (Randot Circles).
Main Methods:
- A comparative study involving 75 healthy young adults using ASTEROID v0.9 and v1.0.
- 31 healthy young adults were tested with the Randot Circles stereotest.
- Stereo thresholds and test/retest repeatability were measured for all participants.
Main Results:
- ASTEROID v1.0 demonstrated significantly lower (better) stereo thresholds than ASTEROID v0.9 by a factor of 1.4.
- Thresholds on ASTEROID v1.0 were comparable to those measured with the Randot Circles stereotest.
- Both versions exhibited similar test/retest repeatability, with a 95% coefficient of repeatability of 0.46 log10 arcsec and a Pearson correlation of 0.8.
Conclusions:
- The improved performance of ASTEROID v1.0 is attributed to the use of smaller, denser dots, resolving the higher thresholds observed with v0.9.
- ASTEROID v1.0 provides stereo thresholds and repeatability consistent with established clinical stereotests.
- The revised version is a viable tool for assessing binocular vision.
Keywords:
binocular visionpsychophysicsstereoacuitystereopsisstereoscopic visionstereotestvision tests