Levonorgestrel release rates measured through analysis of two-rod contraceptive explants
Rachael Fuchs1, Douglas Taylor1, David W Jenkins1
1FHI 360, 359 Blackwell St. Suite 200, Durham, NC 27701, USA.
Objective:
The objective was to characterize and compare in vivo rates of levonorgestrel (LNG) release from Sino-implant (II) and Jadelle® contraceptive implants.
Study Design:
We sampled 48 Sino-implant (II) and 49 Jadelle® explant sets for residual LNG content from participants treated for up to 51 months in a randomized contraceptive efficacy trial in the Dominican Republic (DR). Additional Sino-implant (II) explants were obtained from 8 women who became pregnant in the DR trial and 10 who contributed 3 to 5 years of use in a cohort study in China. Baseline LNG loads were estimated from five unused implant sets per device type. Release profiles were estimated using mixture models that captured initial burst fractions and compared with efficacy and pharmacokinetics data from the DR trial.
Results:
Estimated baseline LNG loads for Sino-implant (II) and Jadelle® were 142.8 mg and 150.5 mg, respectively (vs. the labeled 150 mg). There was an initial burst release of drug (5.6% and 7.9%, respectively) followed by an exponential decrease in LNG content evident for each device. Release rates were significantly lower for Sino-implant (II) throughout the treatment period, with estimated rates after 3 years of 24.2 mcg/day and 29.0 mcg/day for Sino-implant (II) and Jadelle®, respectively. The estimated Sino-implant (II) rate after 3 years was similar to the predicted rate after 5 years (23.6 mcg/day) for Jadelle® (rate ratio: 1.03; 95% confidence interval: 0.92-1.13).
Conclusions:
Sino-implant (II) LNG release rates were significantly lower than Jadelle® with Sino-implant (II) rates through year 3 comparable to Jadelle® rates through year 5. These results reinforce the 3-year duration of action for which Sino-implant (II) was prequalified by the World Health Organization.
Implications:
This analysis confirms the WHO prequalification of Sino-implant (II) for 3 years of use and supports different durations of action for Jadelle® and Sino-implant (II). It provides additional evidence that this approach can complement efficacy trials in determining duration of action of hormonal contraceptives in general.
Related Concept Videos
Birth Control Methods
Hormonal Regulation of the Menstrual Cycle
At puberty, GnRH begins a pulsatile release pattern, which triggers the anterior pituitary gland to secrete follicle-stimulating hormone (FSH) and luteinizing hormone (LH). The frequency and amplitude of GnRH pulses vary across the menstrual cycle, with faster pulses favoring LH release and slower pulses favoring FSH...
Ovarian Cycle
Hormonal Control of the Ovarian Cycle
Before puberty, the hypothalamus releases GnRH in a low frequency, low amplitude pulsatile manner. This along with the immature hypothalamic-pituitary-gonadal axis activity, results in low estrogen levels and the absence of a fully functional ovarian cycle. At puberty, GnRH secretion increases in both frequency and...
In Vitro Drug Release Testing: Overview, Development and Validation