Related Experiment Video
Updated: Dec 7, 2025

Diagnosis of Neoplasia in Barrett’s Esophagus using Vital-dye Enhanced Fluorescence Imaging
Published on: May 11, 2014
Diagnostic accuracy of a novel third generation esophageal capsule as a non-invasive detection method for Barrett's
Abhiram Duvvuri1, Madhav Desai1, Sreekar Vennelaganti1
1Department of Gastroenterology, Kansas City VA Medical Center, Kansas City, Missouri, USA.
Background And Aim:
Previous two generations of esophageal capsule did not show adequate detection rates for Barrett's esophagus (BE). We assessed the diagnostic accuracy of a novel third generation capsule with an improved frame rate of 35 frames per second for the detection of BE in a pilot study.
Methods:
This was a blinded prospective pilot study conducted at a tertiary medical center. Patients with known BE (at least C0M > 1) who presented for endoscopic surveillance (May to October 2017) were included. All patients underwent novel esophageal capsule (PillCam™ UGI; Medtronic) ingestion using the simplified ingestion protocol followed by standard high-definition upper endoscopy (esophagogastroduodenoscopy [EGD]). Capsule endoscopy findings were interpreted by examiners blinded to endoscopy results and compared with endoscopic findings (gold standard). Following completion of both tests, a subjective questionnaire was provided to all patients regarding their experience.
Results:
Twenty patients (95%males, mean age 66.3 [±7.9] years) with BE undergoing surveillance EGD were eligible. The mean BE length was 3.5 (±2.7) cm. Novel esophageal capsule detected BE in 75% patients when images were compared with endoscopy. Novel capsule detected BE in 82% patients when the BE length was ≥2 cm. The mean esophageal transit time was 0.59 s. On a subjective questionnaire, all 20 patients reported novel capsule as being more convenient compared with EGD.
Conclusions:
In this pilot, single-center study, novel esophageal capsule was shown to be not ready for population screening of BE. Studies integrating artificial intelligence into improved quality novel esophageal capsule should be performed for BE screening.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Barrett Esophagus-I: Introduction
This constant acid exposure transforms the esophagus's pink mucosal lining (stratified squamous epithelium) into a type of lining more...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...

