Related Experiment Video
Updated: Dec 7, 2025

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Multimodal combination of GC × GC-HRTOFMS and SIFT-MS for asthma phenotyping using exhaled breath
Pierre-Hugues Stefanuto1, Delphine Zanella2, Joeri Vercammen3,4
1Organic and Biological Analytical Chemistry Group, MOLSYS Research Unit, University of Liège, Allée du 6 Août B6c, 4000, Liège, Belgium. phstefanuto@uliege.be.
Abstract:
Chronic inflammatory lung diseases impact more than 300 million of people worldwide. Because they are not curable, these diseases have a high impact on both the quality of life of patients and the healthcare budget. The stability of patient condition relies mostly on constant treatment adaptation and lung function monitoring. However, due to the variety of inflammation phenotypes, almost one third of the patients receive an ineffective treatment. To improve phenotyping, we evaluated the complementarity of two techniques for exhaled breath analysis: full resolving comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (GC × GC-HRTOFMS) and rapid screening selected ion flow tube MS (SIFT-MS). GC × GC-HRTOFMS has a high resolving power and offers a full overview of sample composition, providing deep insights on the ongoing biology. SIFT-MS is usually used for targeted analyses, allowing rapid classification of samples in defined groups. In this study, we used SIFT-MS in a possible untargeted full-scan mode, where it provides pattern-based classification capacity. We analyzed the exhaled breath of 50 asthmatic patients. Both techniques provided good classification accuracy (around 75%), similar to the efficiency of other clinical tools routinely used for asthma phenotyping. Moreover, our study provides useful information regarding the complementarity of the two techniques.
More Related Videos
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
High-Resolution Mass Spectrometry (HRMS)