Related Experiment Video
Updated: Dec 7, 2025

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Unicuspid aortic valve repair with bicuspidization in the paediatric population
Shunsuke Matsushima1, Alexander Heß1, Julia Renata Lämmerzahl1
1Department of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg/Saar, German.
Objectives:
Aortic stenosis or regurgitation that requires operations in children often results from unicuspid valve morphology. In all paediatric patients with this anomaly, we have performed unicuspid valve repair by bicuspidization, creating a new commissure via adding patch material. This study reviewed our experience with this procedure.
Methods:
All patients with a unicuspid aortic valve who underwent bicuspidization at ≤18 years of age between 2003 and 2018 were evaluated. Autologous pericardium had initially been used for cusp augmentation. Since 2014, decellularized xenogeneic tissue or expanded polytetrafluoroethylene membrane has been applied.
Results:
There were 60 consecutive patients. The median operative age was 13 (1-18) years. Thirty patients had prior surgical or catheter valvuloplasties. Aortic regurgitation, aortic stenosis and their combination were present in 22, 11 and 27 patients, respectively. Autologous pericardium decellularized tissue and expanded polytetrafluoroethylene were used in 45, 11 and 4 patients, respectively, without intraoperative conversion to valve replacement. The overall survival was 96% at 10 years with 2 late deaths. Twenty patients underwent aortic valve reoperation due to patch degeneration (n = 11), suture dehiscence of the patch (n = 3), subaortic stenosis (n = 3) or other reasons (n = 3). Freedom from aortic valve reoperation was 73% and 50% at 5 and 10 years, respectively. Fifteen patients (25%) required valve replacement with pulmonary autograft (n = 14) or prosthesis (n = 1) 5.2 (0.2-13) years after bicuspidization at the age of 19 (10-32) years.
Conclusions:
Bicuspidization is a safe and reproducible alternative to valve replacement with acceptable freedom from reoperation. It can serve as a bridge to valve replacement providing superior outcomes in adults.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022