Estimated Risk for Insulin Dose Error Among Hospital Patients Due to Glucose Meter Hematocrit Bias in 2020

Mark Inman1, Andrew W Lyon2, Oliver A S Lyon3

  • 1From the Department of Pediatrics, University of Saskatchewan, Saskatoon, Saskatchewan, Canada (Inman).

Related Concept Videos

Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
1.2K
Insulin: Dosing Regimen and Adverse Effects01:16

Insulin: Dosing Regimen and Adverse Effects

Insulin-replacement therapy usually includes both long-acting insulin (basal) and short-acting insulin (to cater to postprandial needs). In a diverse group of type 1 diabetes patients, the average daily insulin dose is typically 0.5-0.7 units/kg body weight. However, obese patients and pubertal adolescents may need more due to insulin resistance.
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
523
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration01:28

Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

Glomerular filtration rate (GFR) can be estimated from serum creatinine using the modification of diet in renal disease (MDRD) formula or the chronic kidney disease–epidemiology collaboration (CKD–EPI) equation. Both methods are widely used in clinical practice to assess kidney function and guide treatment decisions.The MDRD equation does not require weight or height measurements and is normalized to the body surface area of 1.73 m², considered the average adult surface area.
90
Hypoglycemia and Glucagon01:15

Hypoglycemia and Glucagon

Without prolonged fasting, healthy individuals maintain blood glucose levels above 3.5 mM due to a well-adapted neuroendocrine counterregulatory system that effectively prevents acute hypoglycemia, a potentially life-threatening condition. The primary clinical scenarios for hypoglycemia encompass diabetes treatment, inappropriate production of endogenous insulin or insulin-like substances by tumors, and the use of glucose-lowering agents in non-diabetic individuals. Notably, hypoglycemia in the...
662
Accuracy and Errors in Hypothesis Testing01:13

Accuracy and Errors in Hypothesis Testing

Hypothesis testing is a fundamental statistical tool that begins with the assumption that the null hypothesis H0 is true. During this process, two types of errors can occur: Type I and Type II. A Type I error refers to the incorrect rejection of a true null hypothesis, while a Type II error involves the failure to reject a false null hypothesis.
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
479
Bias in Epidemiological Studies01:29

Bias in Epidemiological Studies

Biases can arise at various stages of research, from study design and data collection to analysis and interpretation. Recognizing and addressing these biases is essential to ensure the validity and reliability of epidemiological findings.Broadly speaking, biases in epidemiology fall into three main categories: selection bias, information bias, and confounding. A more detailed description of possible biases is:  
1.1K