Related Experiment Video
Updated: Dec 7, 2025

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Commercially Available Polymerase Chain Reaction Has Minimal Utility in the Diagnosis of Periprosthetic Joint
Abstract:
The use of genetic sequencing modalities in the diagnosis of periprosthetic joint infection (PJI) and the identification of organisms has gained popularity recently. Polymerase chain reaction (PCR) offers timely results for common organisms. The purpose of this study was to compare the accuracy of broad-range PCR, conventional culture, the Musculoskeletal Infection Society (MSIS) criteria, and the recently proposed criteria by Parvizi et al in the diagnosis of PJI. In this retrospective study, aspirate or tissue samples were collected in 104 revision and 86 primary arthroplasties for routine diagnostic workup for PJI and sent to the laboratory for PCR. Concordance along with statistical differences between diagnostic studies were calculated using chi-square test for categorical data. On comparison with the MSIS criteria, concordance was significantly lower for PCR at 64.7% compared with 86.3% for culture (P<.001). There was no significant difference based on diagnosis of prior infection (P=.706) or sample collection method (tissue swab or synovial fluid) (P=.316). Of the 87 patients who met MSIS criteria, only 20 (23.0%) PCR samples had an organism identified. In this series, PCR had little utility as a stand-alone test for the diagnosis of PJI, with a sensitivity of only 23.0% when using MSIS criteria as the gold standard. Polymerase chain reaction also appears to be significantly less accurate than culture in the diagnosis of PJI. Currently, several laboratory tests used for either criteria for PJI diagnosis should be obtained along with the overall clinical picture to help guide decision-making for PJI treatment. [Orthopedics. 2020;43(6):333-338.].
Insights
Broad-range polymerase chain reaction (PCR) shows lower accuracy than conventional culture for diagnosing periprosthetic joint infection (PJI). PCR is not recommended as a standalone test for PJI diagnosis.
Area of Science:
- Orthopedics
- Infectious Diseases
- Medical Diagnostics
- Molecular Biology
Background:
- Periprosthetic joint infection (PJI) diagnosis relies on various methods, with genetic sequencing gaining traction.
- Polymerase chain reaction (PCR) offers rapid detection of common pathogens.
- Established diagnostic criteria include the Musculoskeletal Infection Society (MSIS) criteria and newer criteria by Parvizi et al.
Purpose of the Study:
- To compare the diagnostic accuracy of broad-range PCR against conventional culture and established criteria for PJI.
- To evaluate the utility of PCR as a standalone diagnostic tool for PJI.
Main Methods:
- Retrospective study involving 104 revision and 86 primary arthroplasties.
- Aspirate or tissue samples analyzed using broad-range PCR and conventional culture.
- Comparison of PCR and culture results with MSIS and Parvizi et al. criteria.
- Statistical analysis using chi-square test for concordance and differences.
Main Results:
- PCR showed significantly lower concordance (64.7%) compared to culture (86.3%) when compared against MSIS criteria (P<.001).
- PCR sensitivity was only 23.0% when using MSIS criteria as the gold standard.
- No significant difference in accuracy based on prior infection history or sample type (tissue swab vs. synovial fluid).
Conclusions:
- Broad-range PCR demonstrates significantly lower accuracy than conventional culture for PJI diagnosis.
- PCR is not a reliable standalone test for PJI and should be used in conjunction with clinical evaluation.
- Multiple laboratory tests and clinical assessment are crucial for guiding PJI treatment decisions.
More Related Videos
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
PCR