Performance of geotextile-based slow sand filter media in removing total coli for drinking water treatment using
Nurina Fitriani1, Maritha Nilam Kusuma2, Budisantoso Wirjodirdjo3
1Department of Biology, Faculty of Science and Technology, Universitas Airlangga, Kampus C UNAIR, Jalan Mulyorejo, Surabaya 60115, Indonesia.
Abstract:
In a slow sand filter, a biological layer consisting of alluvial mud and various types of microorganisms grows and attaches to the sand media and forms a matrix called schmutzdecke. Changes to several factors, including the quality of raw water, filtration speed, and the addition of media, affect the performance of the slow sand filter unit in producing treated water. Geotextiles can be equipped to improve the performance of a slow sand filter in removing pollutants. The selection of several factors that affect slow sand filter performance can be used as a starting point for the engineering system to determine the best pattern of performance behavior. This approach was carried out by looking at the dynamic behavior patterns of slow sand filter system performance in treating raw water. This research has not yet been conducted extensively. The dynamic behavior pattern approach to the performance of the slow sand filter unit was used to obtain the behavior model for the schmutzdecke layer on the filter. The system dynamic approach focused on treatment scenarios that can determine the behavior of the slow sand filter system. Several factors were assessed, including temperature, turbidity, nutrient concentration, algal concentration, bacteria and dissolved oxygen. Model simulation results show that the comparison of C: N: P values affected the performance of the schmutzdecke layer in removing total coli. The slow sand filter unit was capable of producing treated water with a total amount of coli equal to 0 on the C: N: P values of 85: 5.59: 1.25, respectively, and a 9 cm geotextile thickness.
More Related Videos
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012