Introduction:
Low energy availability (EA) may impede adaptation to exercise, suppressing reproductive function and bone turnover. Exercise energy expenditure (EEE) measurements lack definition and consistency. This study aimed to compare EA measured from moderate and vigorous physical activity from accelerometry (EEEmpva) with EA from total physical activity (EEEtpa) from doubly labeled water in women. The secondary aim was to determine the relationship of EA with physical fitness, body composition by dual-energy x-ray absorptiometry, heart rate variability (HRV), and eating behavior (Brief Eating Disorder in Athletes Questionnaire [BEDA-Q]).
Methods:
This was a prospective, repeated-measures study, assessing EA measures and training adaptation during 11-month basic military training. Forty-seven women (23.9 ± 2.6 yr) completed three consecutive 10-d assessments of EEEmvpa, EEEtpa, and energy intake (EI). EA measures were compared using linear regression and Bland-Altman analyses; relationships of EA with fat mass, HRV, 1.5-mile run times, and BEDA-Q were evaluated using partial correlations.
Results:
EA from EEEmvpa demonstrated strong agreement with EA from EEEtpa across the measurement range (R2 = 0.76, r = 0.87, P < 0.001) and was higher by 10 kcal·kg-1 FFM·d-1. However, EA was low in absolute terms because of underreported EI. Higher EA was associated with improved 1.5-mile run time (r = 0.28, P < 0.001), fat mass loss (r = 0.38, P < 0.001), and lower BEDA-Q score (r = -0.37, P < 0.001) but not HRV (all P > 0.10).
Conclusion:
Accelerometry-based EEE demonstrated validity against doubly labeled water during multistressor training, the difference representing 10 kcal·kg-1 FFM·d-1 EEE from nonexercise activity. Beneficial physical but not autonomic adaptations were associated with higher EA. EAmvpa and BEDA-Q warrant consideration for low EA assessment and screening.
More Related Videos
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...