Person-specific calibration of a partial body counter used for individualised Am241skull measurements
P Nogueira1, W Rühm2
1Thünen Institute of Fisheries Ecology, Herwigstraße 31, 27572 Bremerhaven, Germany.
Abstract:
Incorporation of bone seeking alpha-emitting radionuclides such as241Am are of special concern, due to the potential of alpha particles to damage the extremely radiation-sensitive bone marrow. In the case of an internal contamination with241Am, directin vivomeasurements using Gamma-detectors are typically used to quantify the incorporated activity. Such detectors need to be calibrated with an anatomical phantom, for example of the skull, of known241Am activity that reproduces the anatomy of the measured individual as closely as possible. Any difference in anatomy and material composition between phantom and individual will bias the estimation of the incorporated activity. Consequently, in this work the impact of the most important anatomical parameters on detection efficiency of one of the germanium detectors of the Helmholtz Center Munich (HMGU) partial body counter were systematically studied. For that a detailed model of the germanium detector was implemented in the Monte Carlo codes GEANT4 and MCNPX. To simulate the detector efficiency, various skull voxel phantoms were used. By changing the phantom dimensions and geometry the impact of parameters such as shape and size of the skull, thickness of tissue covering the skull bone, distribution of241Am across the scull and within the skull bone matrix, on the detector efficiency was studied. Approaches to correct for these parameters were specifically developed for three physical skull phantoms for which Voxel phantoms were available: Case 102 USTUR phantom, Max-06 phantom, BfS phantom. Based on the impact of each parameter, correction factors for an 'individual-specific' calibration were calculated and applied to a real241Am contamination case reported in 2014. It was found that the incorporated241Am activity measured with the HMGU partial body counter was about twice as large as that estimated when using the BfS skull phantom without applying any correction factor for person-specific parameters. It is concluded that the approach developed in the present study should in the future be applied routinely for skull phantom measurements, because it allows for a considerably improved reconstruction of incorporated241Am using partial body counters.
More Related Videos
07:30A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
06:48Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024