Estimation of Arterial Blood Pressure Waveform from Photoplethysmogram Signal using Linear Transfer Function Approach
Abstract:
The primary risk factor of hypertension, is the lack of awareness caused by the unavailability of ubiquitous blood pressure (BP) measurement. In this study, we have investigated the BP estimation using the photoplethysmogram (PPG) signal and a suitable subject-specific mathematical model. The linear transfer function (LTF) technique was used to identify the subject-specific model. Firstly, we tried to identify the model considering arterial blood pressure (ABP) as input and PPG as output, and we achieved an average estimation accuracy (normalized root mean square, NRMSE) of 84.4%. Next, we fitted an inverse model, where ABP is the output, and PPG is the input, and we achieved an average estimation accuracy (NRMSE) of 84.7%. Finallly, We verified that the two identified models mentioned above are inverse of each other. In this study, we have used ABP and PPG signals of 10 (male = 7, female = 3) subjets from the MIMIC II database. The results are quite promising for the use of the PPG in the detection and diagnosis of cardiovascular diseases.
More Related Videos
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure