Investigation of a Ballistocardiogram-Based Technique for Unobtrusive Monitoring of Fluid Accumulation in the Body.
Related Experiment Video
Updated: Dec 6, 2025

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Abstract:
We introduce a novel monitoring solution for fluid accumulation in the human body (e.g. internal bleeding), based on observation of a selected energy-describing feature of the Ballistocardiogram (BCG) signal. It is hypothesized that, because of additional damping generated by the fluid, BCG signal energy decreases as compared to its baseline value. Data were collected from 15 human volunteers via accelerometers attached to the participants' body, and an electromechanical-film (EMFi) sensor-equipped bed. Fluid accumulation along the gastrointestinal (GI) tract was induced by means of water intake by the participants, and the BCG signal was recorded before and after intake. Based on performance evaluation, we selected a suitable energy feature and sensing channel amongst the ones investigated. The chosen feature showed a significant decrease in signal energy from baseline to after-intake condition (p-value<0.001), and identified the presence of fluid accumulation with high sensitivity (90% in bed-based, and 100% in standing-position monitoring).
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Body Water Content and Fluid Compartments
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...