Related Experiment Video
Updated: Dec 6, 2025

Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Mitigating Hypovolemia-Induced Miscalibration of Photoplethysmogram-Derived Blood Pressure
Abstract:
Pulse transit time (PTT) is a hemodynamic indicator that may be obtained non-invasively using photoplethysmogram (PPG) signals for continuous blood pressure (BP) monitoring. Among the most promising applications of this technology are military and civilian trauma cases, where reduced blood volume due to hemorrhage, or absolute hypovolemia, is the leading preventable cause of death. However, the drawback of this method is that it requires calibration for each patient; additionally, changes in physiological state may affect PTT calibration. In this work, a porcine model (n = 6) was used to demonstrate that changes in blood volume lead to miscalibration of PTT for BP estimation. To mitigate hypovolemia-induced miscalibration, this work first defines a template-based signal quality index (SQI) for characterizing the morphology of PPG signals; it is then shown that the subject-specific calibration of SQI to BP is more robust to changes in blood volume than PTT. Though changes in PPG signal quality are not necessarily specific to changes in BP, these results suggest that PPG-based monitoring systems may benefit from incorporating morphological information for cuffless BP estimation in trauma settings.
More Related Videos
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Hypertension and Regulation of Blood Pressure