A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Comparison of Three Normalization Methods in Monitoring Analgesic Depth with Photoplethysmographic Diastolic Interval
Abstract:
The purpose of the present study was to investigate the ability of three different normalization methods, namely root mean square (RMS) value, mean value, and maximum which referred to pulse beat interval (PBI), based on photoplethysmographic diastolic interval (DI) in response to laryngeal mask airway (LMA) insertion under various remifentanil concentrations during general anesthesia. Sixty patients were randomly allocated to one of the four groups to receive a possible remifentanil effect-compartment target concentration (Ceremi) of 0, 1, 3, or 5 ng/ml, and an effect-compartment target controlled infusion of propofol to maintain the state entropy (SE) at 40~60. Three normalized measures DIRMS, DIMean, and DIPBI were compared with the DI values without normalization. Before LMA insertion, only DI showed a considerable correlation with remifentanil concentrations. DIRMS and DIMean performed better than DI in discriminating 'insufficient' concentrations (0 and 1 ng/ml) from 'sufficient' concentrations (3 and 5 ng/ml). DIRMS was superior to all other variables in grading analgesic depth after nociceptive event occurred with PK value of 0.836. These results demonstrate that the normalization using RMS value, compared to using mean value and maximum, seems to provide a more effective approach for signal pre-processing.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
10:27Real-Time Assessment of Spinal Cord Microperfusion in a Porcine Model of Ischemia/Reperfusion
Published on: December 10, 2020
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation