Related Experiment Video
Updated: Dec 6, 2025

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
Published on: August 16, 2012
N2NSR-OCT: Simultaneous denoising and super-resolution in optical coherence tomography images using semisupervised
Bin Qiu1,2,3, Yunfei You1,2,3, Zhiyu Huang1,2,3
1Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China.
Abstract:
Optical coherence tomography (OCT) imaging shows a significant potential in clinical routines due to its noninvasive property. However, the quality of OCT images is generally limited by inherent speckle noise of OCT imaging and low sampling rate. To obtain high signal-to-noise ratio (SNR) and high-resolution (HR) OCT images within a short scanning time, we presented a learning-based method to recover high-quality OCT images from noisy and low-resolution OCT images. We proposed a semisupervised learning approach named N2NSR-OCT, to generate denoised and super-resolved OCT images simultaneously using up- and down-sampling networks (U-Net (Semi) and DBPN (Semi)). Additionally, two different super-resolution and denoising models with different upscale factors (2× and 4×) were trained to recover the high-quality OCT image of the corresponding down-sampling rates. The new semisupervised learning approach is able to achieve results comparable with those of supervised learning using up- and down-sampling networks, and can produce better performance than other related state-of-the-art methods in the aspects of maintaining subtle fine retinal structures.
Related Concept Videos
Super-resolution Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Imaging Studies III: Computed Tomography

