A review on maintenance strategies for PV systems

Khaled Osmani1, Ahmad Haddad1, Thierry Lemenand2

  • 1School of Engineering, International University of Beirut BIU, Beirut, Lebanon; School of Engineering, Lebanese International University LIU, Bekaa, Lebanon.

Related Concept Videos

Conservation of AC Power01:15

Conservation of AC Power

The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
529
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the power flow program computes...
603
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
503
P-N junction01:11

P-N junction

A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
940
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
385
Maintenance of the ES Cell State01:14

Maintenance of the ES Cell State

The cells of the blastocyst inner cell mass only remain pluripotent for a short time. This state of pluripotency and self-renewal can be maintained in embryonic stem (ES) cell culture by adding specific chemicals or growth factors to ensure the cells can continue dividing and later differentiate into different cell types. In some cases, the cells are grown on a feeder layer of differentiated cells, which provides the growth factors and extracellular matrix components necessary for stem cell...
2.6K