Related Experiment Video
Updated: Dec 6, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Short-duration, submaximal intensity exercise stress combined with adenosine triphosphate decreases artifacts in
Yukinori Shinoda1, Koichi Tachibana1, Tomoko Minamisaka1
1Department of Cardiovascular Medicine, Yao Municipal Hospital, 1-3-1 Ryuge-cho, Yao, Osaka, 581-0069, Japan.
Background:
Myocardial perfusion single-photon emission computed tomography (SPECT) imaging with stress is a useful examination for detecting coronary artery disease. Since the presence of artifacts is remaining challenges, we aimed to define the minimum intensity of low-grade exercise stress levels combined with drug stress to reduce undesired artifacts and their related factors.
Methods:
We divided patients with suspicious coronary artery disease into 4 groups as follows: group A, adenosine triphosphate (ATP) for 6 min; group A + 25 W, ATP + 25 W exercise for 6 min; group A + 35 W, ATP + 35 W exercise for 6 min; group A + 45 W, ATP + 45 W exercise for 6 min) and enrolled only those whose summed stress scores were < 3. Undesired artifacts were evaluated on the basis of heart-to-liver activity (H/L) ratio and heart-to-10 pixels below the heart (H/below the H) ratio.
Results:
The logarithmic values of H/L and H/below the H ratios were significantly higher in groups A + 35 W and A + 45 W than in group A (p < 0.05, each). In all the patients, the logarithmic values of H/L and H/below the H ratios positively correlated with the increment of rate pressure product (RPP, p = 0.002 and p = 0.005, respectively) after stress in the univariate analysis. The left ventricular end-diastolic volume (LVEDV) after stress (p = 0.002) negatively correlated with the logarithmic value of H/below the H ratio, but not H/L ratio. Although the increment of RPP was independently associated with the logarithmic values of both H/L (p = 0.001) and H/below the H ratios (p = 0.005), LVEDV was also independently associated with the logarithmic value of H/below the H ratio (p < 0.001) in multivariate regression analysis under adjusting with age and sex.
Conclusion:
ATP plus ≥35 W exercise stress for 6 min was useful for reducing undesired artifacts after stress in myocardial perfusion SPECT. LVEDV after stress in addition to the increment of RPP was independently associated with the H/below the H ratio, but not the H/L ratio.
More Related Videos
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT