Related Experiment Video
Updated: Dec 6, 2025

Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
What determines the performance of lanthanide-based ratiometric nanothermometers?
Mochen Jia1, Zhen Sun1, Mingxuan Zhang1
1Coherent Light and Atomic and Molecular Spectroscopy Laboratory, Key Laboratory of Physics and Technology for Advanced Batteries, College of Physics, Jilin University, Changchun 130012, China. zlfu@jlu.edu.cn.
Abstract:
Luminescence intensity ratio (LIR) nanothermometers are ideally suited for noninvasive temperature detection of microelectronic devices and living cells, and the painstaking pursuit of new nanothermometers with higher absolute temperature sensitivity (Sa) or relative temperature sensitivity (Sr) has dominated recent research. However, whether higher Sa and Sr values can intrinsically improve the performance of LIR nanothermometers and what factors essentially determine their accuracy have rarely been considered; these considerations are instructive for their design and application while reducing time and costs. Here, we clarify that the accuracy of lanthanide-based LIR nanothermometers is essentially determined by Sr and the relative error of the luminescence intensity (σI/I) but not Sa based on lanthanide-doped NaYF4, YPO4, YVO4, CaF2, YF3, Y2O3, BaTiO3, LaAlO3 and Y3Al5O12 temperature sensors, meaning that our previous pursuit of higher Sa does not contribute to the accuracy of lanthanide-based LIR nanothermometers. Further research reveals that σI/I is primarily influenced by energy level splitting, which can deteriorate the temperature uncertainty. For actual temperature detection of biological tissues, in addition to the above intrinsic factors, we shed light on the effects of probe self-heating, excitation power density, emission intensity and penetration depth on temperature readouts via a polyethyleneimine-modified NaYF4:Er3+/Yb3+@NaYF4-PEI aqueous solution, implying that we will continue to optimize nanothermometers and calibrate readouts according to the local environment. This work unifies the metrics of lanthanide-based LIR nanothermometers, corrects the previous misunderstanding of Sa to mitigate invalid work, and provides careful guidance for their development.
More Related Videos
08:31Luminescence Resonance Energy Transfer to Study Conformational Changes in Membrane Proteins Expressed in Mammalian Cells
Published on: September 16, 2014
09:38Fabrication Procedures and Birefringence Measurements for Designing Magnetically Responsive Lanthanide Ion Chelating Phospholipid Assemblies
Published on: January 3, 2018
Related Concept Videos
Photoluminescence: Applications
Variables Affecting Phosphorescence and Fluorescence