Paradoxical Motion on Sniff Test Predicts Greater Improvement Following Diaphragm Plication
Deven C Patel1, Mark F Berry1, Prasha Bhandari1
1Division of Thoracic Surgery, Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, California.
Background:
Diaphragm plication (DP) improves pulmonary function and quality of life for those with diaphragm paralysis or dysfunction. It is unknown whether differing degrees of diaphragm dysfunction as measured by sniff testing affect results after plication.
Methods:
Patients who underwent minimally invasive DP from 2008 to 2019 were dichotomized based on sniff test results: paradoxical motion (PM) versus no paradoxical motion (NPM); the latter included normal, decreased, and no motion. Preoperative and postoperative pulmonary function testing (PFT) after DP was compared between groups. The impact of the diaphragm height index, a measure of diaphragm elevation, was also assessed.
Results:
A total of 26 patients underwent preoperative sniff testing, DP, and postoperative PFT. Including all patients, DP resulted in a 17.8% ± 5.5% improvement in forced expiratory volume in 1 second (P < .001), a 14.4% ± 5.3% improvement in forced vital capacity (P < .001), and a 4.7% ± 4.6% improvement in the diffusing capacity of carbon monoxide (P = .539). There were greater improvements in the PM group (n = 16) compared with the NPM group (n = 10) for forced expiratory volume in 1 second (27.2% ± 6.0% versus 3.9% ± 6.2%; P = .017) and forced vital capacity (28.1% ± 5.3% versus -0.5% ± 3.3%; P = .001). There was no difference in the change in the diffusing capacity of carbon monoxide between groups. There were no differences between patients with PM and NPM in the postoperative course or complications. No value for diaphragm height index predicted improvement in PFT after DP.
Conclusions:
Patients with PM on sniff test have dramatically greater objective improvements in pulmonary function after plication compared with those without PM. Most patients without PM do not demonstrate improvement in standard PFT. Improvements in dyspnea require additional study.
Related Concept Videos
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: