Related Experiment Video
Updated: Dec 6, 2025

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Ellipse method for measuring Liaw's anteversion of the acetabular component after total hip arthroplasty
Kuei-Lin Yeh1, Tai-Yin Wu2,3,4, Hsuan-Hsiao Ma5,6
1Department of Orthopedics, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, 11101, Taiwan.
Background:
Several cup anteversion measurements for post-operative total hip arthroplasty (THA) surgery have been described. We developed the standardized Liaw's trigonometric method to eliminate the influence of patient position, which is the most accurate method for cup anteversion measurement. We then developed an ellipse method using the Elliversion software and reported an interobserver error reduction in 2013. In this study, we attempted to apply this ellipse method in the clinic and compared its accuracy with the standard trigonometric version.
Methods:
In the present study, we attempted to incorporate the ellipse method with Liaw's standardized anteversion in the simulated cup position. We measured standardized Liaw's anteversion for 434 radiographs in the clinic using the ellipse method. Repeated standard deviation (RSD) was calculated for accuracy evaluation. Furthermore, paired t-test was used for comparison with the interobserver and intraobserver errors.
Results:
We found that the standardized Liaw's anteversion measured using the ellipse method showed lower RSD than the radiographic version. RSD was 0.795 in the standardized Liaw's anteversion with ellipse method group. The p-values of the paired t-test were all higher than 0.05 when measuring the interobserver and intraobserver errors. It indicated that the ellipse method was a precise and simple tool for cup anteversion measurement.
Conclusion:
We believe that this ellipse measurement can assist surgeons while placing the acetabulum cup into the precise position and enable early diagnosis of acetabulum loosening.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
06:16A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
Published on: May 1, 2020