Related Experiment Video
Updated: Dec 6, 2025

Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
The Cardiac Pacemaker Clinic: Memories From a Bygone Era
Harry G Mond1, J Graeme Sloman2
1Department of Cardiology, The Royal Melbourne Hospital and the Department of Medicine, University of Melbourne, Melbourne, Vic, Australia.
Abstract:
In 1963, soon after the first ventricular pacemakers were implanted at the Royal Melbourne Hospital, attempts were made to identify impending pacing failure, thus preventing sudden death in these very vulnerable patients. By 1970, patient numbers had increased, a formal regular pacemaker clinic was established, and guidelines and protocols developed. The clinic was staffed by a physician, a biomedical engineer and cardiac technicians. The unipolar, asynchronous, non-programmable pulse generators were powered by mercuric oxide/zinc batteries and implanted in the abdomen, using either transvenous or epimyocardial leads. Although, pulse generators were electively replaced at 3 years, most had already been replaced because of power source depletion, electronic failure or lead issues. Testing in all patients involved an electrocardiographic rhythm strip and electronic analysis of the stimulus artefact using a calibrated high-speed storage oscilloscope. Results were compared to previous studies and significant changes were interpreted as impending power source depletion. As a result of this testing, 97% of cases of impending power source depletion were detected prior to failure. These findings allowed testing each 4 months and for pulse generator life to be extended beyond three years. With ventricular triggered pulse generators, new testing procedures were designed. With time, visiting regional centres and clinical evaluation of new products became important functions of the clinic.
More Related Videos
08:52Generation of Murine Cardiac Pacemaker Cell Aggregates Based on ES-Cell-Programming in Combination with Myh6-Promoter-Selection
Published on: February 17, 2015
08:56Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Cardiac Catheterization I: Pre-Procedure Overview
Introduction Cardiac Emergencies
Cardiac Catheterization III: Left Heart Catheterization