Concentration-dependent Differences in Urinary Iodine Measurements Between Inductively Coupled Plasma Mass
Yongze Li1, Shuangning Ding1, Cheng Han1,2
1Department of Endocrinology and Metabolism and the Institute of Endocrinology, First Hospital of China Medical University, No.155 Nanjing Bei Street, Shenyang, 110001, Liaoning, China.
Abstract:
A large amount of historical data regarding urinary iodine concentration (UIC) were measured with the Sandell-Kolthoff (S-K) method for iodine nutrition surveillance. The congruence in urinary iodine measurements between inductively coupled plasma mass spectrometry (ICP-MS) and the S-K method has been debated. A total of 2064 adult urine samples were included in the present study. The UIC measurement results obtained simultaneously by standardized ICP-MS and the S-K method were analyzed. The UIC obtained with ICP-MS was significantly higher than that obtained with the S-K method (158 μg/L vs. 148 μg/L, p < 0.001). The Bland-Altman difference plot showed a small but significant mean difference of 6.12 μg/L between the two methods. The stratified analysis showed that the correlation coefficient was higher in the UIC < 300 μg/L group than the UIC ≥ 300 μg/L group (0.93 vs. 0.88, p = 0.0001). The mean difference between the S-K and ICP-MS methods was positively correlated with the UIC. The ICP-MS and S-K methods were comparable when the UIC was less than 300 μg/L; however, UIC values between 300 and 600 μg/L should be compared with caution after considering the research objective. We do not suggest comparing UICs obtained from the ICP-MS and S-K methods in iodine monitoring studies if the UIC is greater than 600 μg/L.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Precipitation Titration Curve: Analysis
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: