Surface Composition and Aerosolization Stability of an Inhalable Combinational Powder Formulation Spray Dried Using a

Nivedita Shetty1,2, Yiwen Zhang1, Heejun Park1

  • 1Department of Industrial and Physical Pharmacy, College of Pharmacy, Purdue University, 575 Stadium Mall Drive, West Lafayette, Indiana, 47907, USA.

Pharmaceutical Research
|October 10, 2020
PubMed
Abstract

Related Concept Videos

Inhaled Medications01:23

Inhaled Medications

Inhaled medications are crucial for managing chronic obstructive pulmonary disease (COPD) and asthma. They are essential for effective treatment and control, ensuring optimal respiratory health and well-being. Inhaled medication delivers drugs directly to the lungs, providing a rapid onset of action and reducing systemic side effects compared to oral or injectable medications. Three primary types of inhalation devices are used to administer these medications: nebulizers, metered-dose inhalers...
594
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
1.2K
Precipitate Formation and Particle Size Control01:16

Precipitate Formation and Particle Size Control

In precipitation gravimetry, the precipitating agent should react specifically or selectively with the analyte. While a specific reagent reacts with the analyte alone, a selective reagent can react with a limited number of chemical species.
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
3.9K
Factors Affecting Dissolution: Particle Size and Effective Surface Area01:23

Factors Affecting Dissolution: Particle Size and Effective Surface Area

Dissolution kinetics, an essential aspect of oral drug delivery, is significantly influenced by the drug's particle size. According to the Noyes-Whitney dissolution model, the dissolution rate correlates directly with the drug's surface area. The larger the surface area, the higher the drug's solubility in water, leading to a faster drug dissolution rate. Reducing particle size increases the effective surface area, enhancing the dissolution process. Micronization and nanosizing are...
1.4K
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
701