Assessment of dead-end ultrafiltration for the detection and quantification of microbial indicators and pathogens in
Miriam Pascual-Benito1, Pere Emiliano2, Raquel Casas-Mangas1
1Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, 08028, Barcelona, Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001, Barcelona, Spain.
Abstract:
A safe water supply requires distinct treatments and monitoring to guarantee the absence of pathogens and substances potentially hazardous for human health. In this study we assessed the efficiency of the dead-end ultrafiltration (DEUF) method to concentrate faecal indicator organisms (FIO) and pathogens in water samples with different physicochemical characteristics. Water samples were collected at the treatment stages of two drinking water treatment plants to analyse the concentration of a variety of 7 FIO and 4 reference microbes which have some species that are pathogenic to humans: Campylobacter spp., enteroviruses, Cryptosporidium spp. and Giardia spp. The samples were analysed before and after concentration by DEUF, detecting FIO concentrations about 1 log10 higher in non-concentrated samples from both catchments. Percent recoveries were highly variable with a mean of 43.8 ± 17.5%, depending on the FIO and inherent sample characteristics. However, DEUF enabled FIO concentration in high volumes of water (100-500 l), allowing a reduction in the detection limit compared to the non-concentrated samples due to the high volume processing capabilities of the method. As a consequence, the detection of FIO removal from water in the drinking water treatment process was 1.0-1.5 logarithms greater in DEUF-treated water compared to unfiltered samples. The DEUF method improved the detection of target indicators and allowed for the detection of pathogens in low concentrations in water after the treatment stages, confirming the suitability of DEUF to concentrate high volumes of different types of water. This method could be useful for microbial analysis in water treatment monitoring and risk assessment, allowing the identification of critical points during the water treatment process and potential hazards in water destined for several uses.
More Related Videos
12:14A Duplex Digital PCR Assay for Simultaneous Quantification of the Enterococcus spp. and the Human Fecal-associated HF183 Marker in Waters
Published on: March 9, 2016
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016