Furosemide administration onehour before bone scintigraphy examination in horses does not improve the image quality
Mahmoud Mageed1, Julius Wegert1, Shahlaa Dyab1
1Tierklinik Lüsche GmbH, Tierklinik Lüsche GmbH, Essenerstr. 39a, Bakum, 49456, Germany.
Abstract:
This prospective, cross-sectional, pilot study aimed to investigate the effects of furosemide as a diuretic on the image quality of bone scintigraphy performed using 99m Tc-HDP and to investigate the impact of furosemide on the radiation dose rate. Thirty-one horses undergoing bone scintigraphy were included. The horses were divided into the control (n = 14) and furosemide group (n = 17), which received 1 mg/kg furosemide intravenously 1 h post 99m Tc-HDP administration. The image quality was assessed subjectively and semi-quantitatively. The bone-to-soft tissue (B:S) ratio was calculated from the counts per pixel of regions of interest (ROI) positioned over the left radial diaphysis (bone ROI) and its caudal soft tissue area (soft tissue ROI). The radiation rate dose (μSv/h) of both groups was measured at 0, 3, 6, 12, 18, and 24 h post 99m Tc-HDP administration at a distance of 0, 30, and 100 cm from the head, kidney, and pelvis. The results showed no significant differences in the B:S ratio or the radiation dose rate observed between the groups. However, the radiation dose rate decreased by 56% at 3 h post 99m Tc-HDP administration and keeping a distance of 30 cm reduced the radiation dose rate by 65%. Administering furosemide does not improve the image quality or reduce the radiation dose rate. The authors recommend commencing with bone scintigraphy 3 h post 99m Tc-HDP administration and keeping at least a distance of 30 cm from the horse to reduce the staff radiation dose.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
06:38Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Ultrasonography
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Imaging Studies IV: Magnetic Resonance Imaging