Related Experiment Video
Updated: Dec 6, 2025

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Evaluation of the response of esthetic restorative materials to ultraviolet aging
Yu-Sung Choi1, Ki-Ho Kang2, Wael Att3
1Associate Professor, Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea; Visiting Professor, Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass.
Statement Of Problem:
The optical properties of esthetic computer-aided design and computer-aided manufacturing (CAD-CAM) materials can change depending on the clinical situation. Studies that compare esthetic CAD-CAM materials based on their optical properties are lacking.
Purpose:
The purpose of this in vitro study was to evaluate the optical properties of esthetic CAD-CAM specimens after ultraviolet (UV) aging based on the type and thickness of the material.
Material And Methods:
In total, 240 plate-shaped specimens (14×12×1 mm and 14×12×2 mm) of a nanohybrid composite resin (Tetric CAD), a fine-structure feldspathic ceramic (Vitablocs Mark II), 2 different glass-ceramics (IPS Empress CAD and IPS e.max CAD), a zirconia-reinforced lithium silicate glass-ceramic (Celtra Duo), a polymer-infiltrated ceramic network (Vita Enamic), and 2 different resin nanoceramics (Cerasmart and Lava Ultimate) were fabricated (n=15). The optical parameters were analyzed by spectrophotometry before and after UV aging. The brightness (L∗), red green (a∗), yellow-blue (b∗), chroma (Ch), and hue (h) were measured, and the color difference (ΔE00) values were calculated. The translucency parameter (TP), total transmittance (Tt), and contrast ratio (CR) were also determined. Statistical analyses were performed with 1-way ANOVA, the Tukey honestly significant difference post hoc test, independent- and paired-samples t tests, and 2-way ANOVA (α=.05).
Results:
Significant interactions were observed for the aging process, material type, and thickness for all optical parameters (P<.05). L∗, TP, and Tt had lower values, while CR had higher values for the aging group than that of the control group (P<.05). The h, TP, and Tt values were higher, whereas the b∗ and CR values were lower for the 1-mm group than those of the 2-mm group (P<.05). The highest ΔE00 value was found in the Lava Ultimate 1-mm group (ΔE00=3.21) and 2-mm group (ΔE00=2.42). The lowest ΔE00 value was found in the Vitablocs Mark II 1-mm group (ΔE00=0.31). The highest TP and Tt and the lowest CR values were observed for Tetric CAD; the lowest TP and Tt, and the highest CR values were noted in Celtra Duo (P<.05).
Conclusions:
The optical properties of the CAD-CAM specimens were affected by the aging process, material type, and thickness, and the color stability was clinically applicable in all CAD-CAM materials except groups Lava Ultimate and Cerasmart(ΔE00<2.25). Resin nanoceramics exhibited the greatest color changes after UV aging, and a 2-mm thickness is recommended to ensure acceptable color stability. The zirconia-reinforced lithium silicate glass-ceramic was the most opaque, with a 1-mm thickness providing increased translucency.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022