Related Experiment Video
Updated: Dec 6, 2025

Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
Does prior mediastinal lymph node aspiration contribute to false-positive positron emission tomography-computed
J Michael Ramsahai1, Christine Molnar2, Lawrence Lou2
1Division of Respiratory Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
Background:
Proper staging of the mediastinum is an essential component of lung cancer evaluation. Positron emission tomography-computed tomography (PETCT) and endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) are an integral part of this process. False-positive PETCT results can occur following surgical procedures but has not been demonstrated following EBUS-TBNA. We aimed to determine whether false-positive PETCT rates increase when EBUS-TBNA is performed prior to PETCT.
Study Design And Methods:
A retrospective review was carried out of clinical cases that underwent both PETCT and EBUS-TBNA within 30 days for the suspected malignancy. The impact of test sequence on the PETCT false-positive rate (FPR) was determined using Generalised Estimating Equation logistic regression analysis.
Results:
A total of 675 lymph node stations were sampled and imaged on PETCT. Overall, 332 (49.2%) nodes were sampled by EBUS-TBNA before PETCT, and 343 (50.8%) afterwards, with the interval between EBUS and subsequent PETCT being a mean±sd of 11.6±6.8 days (range 1-29). The FPR on qualitative PETCT for the EBUS first group was 41 (23.2%) out of 164, and for PETCT first it was 57 (29.0%) out of 193 for a difference of 5.8% (95% CI -3.4-14.7, p=0.22). In the regression model, EBUS as the first test was associated with a lower FPR when using the clinical PETCT interpretation.
Interpretation:
The performance of EBUS-TBNA sampling did not influence the FPR of PETCT when bronchoscopy took place in the 30 days prior to testing. Test sequence should be selected based on other clinical considerations.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...