Related Experiment Video
Updated: Dec 6, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Orally Inhaled Drug Particle Transport in Computerized Models of Laryngotracheal Stenosis
Dennis Onyeka Frank-Ito1,2,3, Seth Morris Cohen1
1Department of Head and Neck Surgery & Communication Sciences, Duke University Medical Center, Durham, North Carolina, USA.
Objective:
Adjuvant management for laryngotracheal stenosis (LTS) may involve inhaled corticosteroids, but metered dose inhalers are designed for pulmonary drug delivery. Comprehensive analyses of drug particle deposition efficiency for orally inhaled corticosteroids in the stenosis of LTS subjects are lacking.
Study Design:
Descriptive research.
Setting:
Academic medical center.
Methods:
Anatomically realistic 3-dimensional reconstructions of the upper airway were created from computed tomography images of 4 LTS subjects-2 subglottic stenosis and 2 tracheal stenosis subjects. Computational fluid dynamics modeling was used to simulate airflow and drug particle transport in each airway. Three inhalation pressures were simulated, 10 Pa, 25 Pa, and 40 Pa. Drug particle transport was simulated for 100 to 950 nanoparticles and 1 to 50 micron-particles. Particles were released into the airway to mimic varying inhaler conditions with and without a spacer chamber.
Results:
Based on smallest to largest cross-sectional area ratio, the laryngotracheal stenotic segment shrunk by 57% and 47%, respectively, for subglottic stenosis models and by 53% for both tracheal stenosis models. Airflow resistance at the stenotic segment was lower in subglottic stenosis models than in tracheal stenosis models: 0.001 to 0.011 Pa.s/mL vs 0.024 to 0.082 Pa.s/mL. Drug depositions for micron-particles and nanoparticles at stenosis were 0.06% to 2.48% and 0.10% to 2.60% for subglottic stenosis and tracheal stenosis models, respectively. Particle sizes with highest stenotic deposition were 6 to 20 µm for subglottic stenosis models and 1 to 10 µm for tracheal stenosis models.
Conclusion:
This study suggests that at most, 2.60% of inhaled drug particles deposit at the stenosis. Particle size ranges with highest stenotic deposition may not represent typical sizes emitted by inhalers.
More Related Videos
Related Concept Videos
Inhaled Medications
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...