Checking the pulse in the 21st century: Interobserver reliability of carotid pulse detection by point-of-care
David J Smith1, Robert Simard2, Jordan Chenkin2
1Division of Emergency Medicine, University of Toronto, C. David Naylor Building, 3rd Floor 6 Queen's Park Crescent West, Toronto, ON M5S 3H2, Canada.
Introduction:
Detection of a pulse is crucial to decision-making in the care of patients who are in cardiac arrest, however, the current standard of manual pulse palpation is unreliable. An emerging alternative is the use of point-of-care ultrasound (POCUS) for direct assessment of the carotid pulse. The primary objective of this study is to determine the interobserver reliability for physician interpretation of pre-recorded point-of-care ultrasound pulse-check clips for patients who are in cardiac arrest.
Methods:
We conducted a web-based survey of residents and physicians working in an academic center. Participants were shown a tutorial demonstrating POCUS detection of the carotid pulse and then asked to interpret 15 carotid pulse ultrasound clips from patients who were in cardiac arrest. The primary outcome was interobserver reliability for carotid pulse assessment. Secondary outcomes included interobserver reliability stratified by physician role and POCUS experience, median tutorial and median pulse assessment duration. Interobserver reliability was determined by Krippendorff's ⍺.
Results:
68 participants completed the study, with a response rate of 75%. There was high interobserver reliability for pulse assessment amongst all study participants (⍺ = 0.874, 95% CI 0.869 to 0.879). All sub-groups had ⍺ greater than 0.8. Median tutorial duration was 35 s (IQR 29). Median pulse assessment duration was 6 s (IQR 5) with 76% of assessments completed within 10 s.
Conclusion:
Interpretation of the carotid pulse by POCUS showed high interobserver reliability. Further work must be done to determine the performance of POCUS pulse assessment in real-time for patients who are in cardiac arrest.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical...