Validity of Smartphone Heart Rate Variability Pre- and Post-Resistance Exercise
Clifton J Holmes1,2, Michael V Fedewa2, Lee J Winchester2
1Program in Physical Therapy, Washington University School of Medicine, St. Louis, MO 63110, USA.
Abstract:
The aim was to examine the validity of heart rate variability (HRV) measurements from photoplethysmography (PPG) via a smartphone application pre- and post-resistance exercise (RE) and to examine the intraday and interday reliability of the smartphone PPG method. Thirty-one adults underwent two simultaneous ultrashort-term electrocardiograph (ECG) and PPG measurements followed by 1-repetition maximum testing for back squats, bench presses, and bent-over rows. The participants then performed RE, where simultaneous ultrashort-term ECG and PPG measurements were taken: two pre- and one post-exercise. The natural logarithm of the root mean square of successive normal-to-normal (R-R) differences (LnRMSSD) values were compared with paired-sample t-tests, Pearson product correlations, Cohen's d effect sizes (ESs), and Bland-Altman analysis. Intra-class correlations (ICC) were determined between PPG LnRMSSDs. Significant, small-moderate differences were found for all measurements between ECG and PPG: BasePre1 (ES = 0.42), BasePre2 (0.30), REPre1 (0.26), REPre2 (0.36), and REPost (1.14). The correlations ranged from moderate to very large: BasePre1 (r = 0.59), BasePre2 (r = 0.63), REPre1 (r = 0.63), REPre2 (r = 0.76), and REPost (r = 0.41)-all p < 0.05. The agreement for all the measurements was "moderate" (0.10-0.16). The PPG LnRMSSD exhibited "nearly-perfect" intraday reliability (ICC = 0.91) and "very large" interday reliability (0.88). The smartphone PPG was comparable to the ECG for measuring HRV at rest, but with larger error after resistance exercise.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...