Related Experiment Video
Updated: Dec 6, 2025

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Atrial Reservoir Strain is Associated with Decreased Cardiac Index and Adverse Outcomes Post Fontan Operation
Daniel Peck1, Tarek Alsaied2, Sarah Pradhan2
1The Heart Institute, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, MLC 2003, Cincinnati, OH, 45229, USA. daniel.peck@cchmc.org.
Abstract:
Fontan patients rely on atrial function for diastolic filling and to augment cardiac output. Emerging data suggests that diminished atrial function is predictive of poor outcomes in adults but studies evaluating the association between atrial mechanics in Fontan patients and outcomes are lacking. We sought to assess atrial function in Fontan patients using speckle tracking echocardiography to determine whether atrial function is associated with invasive hemodynamics and clinical outcomes. Single-center review of Fontan patients receiving both catheterization and echocardiogram from 2012-2017. Atrial reservoir, conduit and pump global longitudinal strain and strain rate were assessed by speckle tracking echocardiography. The primary outcome was a composite of all adverse clinical outcomes including cardiac hospitalizations, transplant and death. Eighty-three Fontan patients at a median age of 14.2 years (IQR 8.6, 21.7) at time of echocardiogram were included. Increased atrial reservoir strain (p = 0.04), atrial emptying fraction (p = 0.04) and atrial fractional area change (p = 0.04), were associated with higher cardiac index at baseline. There were no associations between atrial strain and systemic ventricular end diastolic pressure (EDP) at catheterization. Reservoir strain was inversely associated with the composite clinical outcome on multivariable Cox proportional hazard analysis (HR 0.96, p = 0.03). Reduced atrial function is associated with reduced cardiac index, but is not directly associated with ventricular EDP in Fontan patients. Reservoir strain is associated with an excess of adverse clinical outcomes in Fontan patients.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Mitral Stenosis I: Introduction
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Mitral Regurgitation I: Introduction
Heart Failure II: Pathophysiology
Aortic Regurgitation III: Medical Management
Mitral Stenosis IV: Nursing Management