A survey of pathways for mechano-electric coupling in the atria
Marta Varela1, Aditi Roy2, Jack Lee3
1National Heart and Lung Institute, Faculty of Medicine, Imperial College London, London, UK; Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK.
Abstract:
Mechano-electric coupling (MEC) in atrial tissue has received sparse investigation to date, despite the well-known association between chronic atrial dilation and atrial fibrillation (AF). Of note, no fewer than six different mechanisms pertaining to stretch-activated channels, cellular capacitance and geometric effects have been identified in the literature as potential players. In this mini review, we briefly survey each of these pathways to MEC. We then perform computational simulations using single cell and tissue models in presence of various stretch regimes and MEC pathways. This allows us to assess the relative significance of each pathway in determining action potential duration, conduction velocity and rotor stability. For chronic atrial stretch, we find that stretch-induced alterations in membrane capacitance decrease conduction velocity and increase action potential duration, in agreement with experimental findings. In the presence of time-dependent passive atrial stretch, stretch-activated channels play the largest role, leading to after-depolarizations and rotor hypermeandering. These findings suggest that physiological atrial stretches, such as passive stretch during the atrial reservoir phase, may play an important part in the mechanisms of atrial arrhythmogenesis.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Chambers of the Heart
Deoxygenated blood from the body is received in the right...
Structure of Cardiac Muscles
Compared to skeletal muscles, cardiac muscle cells are small and mostly have a single nucleus. Additionally, they are usually...