Related Experiment Video
Updated: Dec 5, 2025

05:51
Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
18.2K
Pulse Wave Velocity in Systemic Sclerosis: Potential Beneficial Effects of Bosentan on Forearm Arterial Stiffness? An
Anniek Maaike van Roon1,2, Amaal Eman Abdulle3, Douwe Johannes Mulder3
1Department of Internal Medicine, Division of Vascular Medicine; a.m.van.roon01@umcg.nl.
The Journal of Rheumatology
|October 16, 2020
Abstract
No abstract available in PubMed .
Related Concept Videos
Peripheral Artery Disease I: Introduction
189
Peripheral artery disease (PAD) predominantly results from atherosclerosis, which involves the accumulation of fatty deposits, or plaques, within the walls of arteries. This causes them to narrow and harden, significantly reducing blood flow. PAD predominantly affects the legs, particularly the arteries supplying the thighs and calves. In rare cases, it may involve other arteries, including those in the arms.Etiology of PAD:The principal cause of PAD is atherosclerosis, which results from fatty...
189
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
209
Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
209
Assessment of blood pressure in brachial artery(two-step method)
1.3K
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.3K
Assessing Blood pressure using a doppler ultrasound
2.1K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.1K
Assessing Blood pressure in the Leg
7.0K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
7.0K
Assessment of blood pressure in brachial artery(one-step method)
934
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
934