Related Experiment Video
Updated: Dec 5, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Neoadjuvant breast cancer treatment response; tumor size evaluation through different conventional imaging modalities
Ida Skarping1, Daniel Förnvik2, Uffe Heide-Jørgensen3
1Department of Clinical Sciences, Division of Oncology and Pathology, Lund University, Skåne University Hospital, Lund, Sweden.
Background:
Neoadjuvant chemotherapy (NACT) is offered to an increasing number of breast cancer (BC) patients, and comprehensive monitoring of treatment response is of utmost importance. Several imaging modalities are available to follow tumor response, although likely to provide different clinical information. We aimed to examine the association between early radiological response by three conventional imaging modalities and pathological complete response (pCR). Further, we investigated the agreement between these modalities pre-, during, and post-NACT, and the accuracy of predicting pathological residual tumor burden by these imaging modalities post-NACT.
Material And Methods:
This prospective Swedish cohort study included 202 BC patients assigned to NACT (2014-2019). Breast imaging with clinically used modalities: mammography, ultrasound, and tomosynthesis was performed pre-, during, and post-NACT. We investigated the agreement of tumor size by the different imaging modalities, and their accuracy of tumor size estimation. Patients with a radiological complete response or radiological partial response (≥30% decrease in tumor diameter) during NACT were classified as radiological early responders.
Results:
Patients with an early radiological response by ultrasound had 2.9 times higher chance of pCR than early radiological non-responders; the corresponding relative chance for mammography and tomosynthesis tumor size measures was 1.8 and 2.8, respectively. Post-NACT, each modality, separately, could accurately estimate tumor size (within 5 mm margin compared to pathological evaluation) in 43-46% of all tumors. The diagnostic precision in predicting pCR post-NACT was similar between the three imaging modalities; however, tomosynthesis had slightly higher specificity and positive predictive values.
Conclusion:
Breast imaging modalities correctly estimated pathological tumor size in less than half of the tumors. Based on this finding, predicting residual tumor size post-NACT is challenging using conventional imaging. Patients with early radiological non-response might need improved monitoring during NACT and be considered for changed treatment plans.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
10:13Non-Destructive Evaluation of Regional Cell Density Within Tumor Aggregates Following Drug Treatment
Published on: June 21, 2022