Related Experiment Video
Updated: Dec 5, 2025

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Acute effects of transcatheter aortic valve replacement on the ventricular-aortic interaction
Stamatia Pagoulatou1, Nikolaos Stergiopulos1, Vasiliki Bikia1
1Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Abstract:
Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis (AS) patients. However, little is known regarding the direct effect of TAVR on the ventricular-aortic interaction. In the present study, we aimed to investigate changes in central hemodynamics after successful TAVR. We retrospectively examined 33 cases of severe AS patients (84 ± 6 yr) who underwent TAVR. Invasive measurements of left ventricular and aortic pressures as well as echocardiographic aortic flow were acquired before and after TAVR (maximum within 5 days). We examined alterations in key features of central pressure and flow waveforms, including the aortic augmentation index (AIx), and performed wave separation analysis. Arterial parameters were determined via parameter-fitting on a two-element Windkessel model. Resolution of AS resulted in direct increase in the aortic systolic pressure and maximal aortic flow (131 ± 22 vs. 157 ± 25 mmHg and 237 ± 49 vs. 302 ± 69 mL/s, P < 0.001 for all), whereas the ejection duration decreased (P < 0.001). We noted a significant decrease in the AIx (from 42 ± 12 to 19 ± 11%, P < 0.001). Of note, the arterial properties remained unchanged. There was a comparable increase in both forward (61 ± 20 vs. 77 ± 20 mmHg, P < 0.001) and backward (35 ± 14 vs. 42 ± 10 mmHg, P = 0.013) pressure wave amplitudes, while their ratio, i.e., the reflection coefficient, was preserved. Our results highlight the impact of TAVR on the ventricular-aortic interaction by affecting the amplitude, shape, and related attributes of the aortic pressure and flow pulse and challenge the interpretation of AIx as a solely vascular measure in AS patients.NEW & NOTEWORTHY Transcatheter aortic valve replacement (TAVR) is linked with an immediate increase in aortic systolic blood pressure and maximal flow, as well as steeper aortic pressure and flow wave upstrokes. After TAVR, the forward wave pumped by the heart is enhanced. Although the arterial properties remain unchanged, the central augmentation index (AIx) is markedly decreased after TAVR. This challenges the interpretation of AIx as a solely vascular measure in patients with aortic valve stenosis.
More Related Videos
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Aortic Regurgitation IV: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...

