Published on: June 11, 2012
Comparison of IV oncology infusions compounded via robotics and gravimetrics-assisted workflow processes
Bob Pang1, Marc Earl1, Scott Knoer1,2
1Cleveland Clinic, Cleveland, OH.
Purpose:
A study was conducted to compare an intravenous (IV) gravimetric technology-assisted workflow (TAWF) platform to an IV robotic system. In the study we reviewed both IV technology platforms using the same gravimetric quality assurance system, which allowed for direct comparison.
Methods:
All oncology preparations compounded from January 2016 through December 2018 using either system were included in our retrospective analysis. Final preparation accuracy, IV system precision, and workflow throughput (analyzed using lean process methodologies) were evaluated.
Results:
Data analysis indicated that use of the IV gravimetric TAWF system was associated with a significantly lower percentage of accuracy errors compared to the IV robotics system (1.58% vs 2.47%, P < 0.001), with no significant difference in absolute precision (1.12 vs 1.12 P = 0.952). Lean analysis demonstrated that overall completion time (17:49 minutes vs 24:45 minutes) and compound preparation time (2:39 minutes vs 6:07 minutes) were less with the IV gravimetric TAWF vs the IV robotics system.
Conclusion:
Implementation of either an IV gravimetric TAWF system or IV robotics system will result in similar compounding accuracy and precision. Preparation time was less with use of the IV gravimetric TAWF vs the IV robotic system, but the IV robotic system required less human intervention. Both systems ensure medication safety for patients, although the IV robotic system has increased safeguards in place. Therefore, the primary driver for implementing these systems is alternative factors such as cost of systems implementation and maintenance, employee safety, and drug waste.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...