Related Experiment Video
Updated: Dec 5, 2025

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
A chemometric comparison of different models in fluorescence analysis of dabigatran etexilate and dabigatran
Tong Wang1, Qian Liu2, Wan-Jun Long1
1State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China.
Abstract:
In this paper, a simple, rapid, low-cost and potential method was established for the simultaneous quantitative analysis of dabigatran etexilate (DABE) and dabigatran (DAB) in spiked biological fluids. It combined excitation-emission matrix fluorescence (EEMF) with different second-order calibration methods, including the self-weighted alternating normalized residue fitting (SWANRF) algorithm based on trilinear decomposition model, the multivariate curve resolution - alternating least-squares (MCR-ALS) based on bilinear decomposition model and the unfolded partial least-square coupled with residual bilinearization (U-PLS/RBL) based on latent variables model. The proposed method showed "second-order advantage", that is, satisfactory quantitative results were successfully obtained even in the presence of unknown interferences and serious spectral overlap. The recoveries of DABE and DAB in spiked biological fluids were 91.7%-101.7% for SWANRF, 95.9%-117.8% for MCR-ALS, 83.0%-109.6% for U-PLS/RBL, respectively. Figures of merit and other statistical parameters were also calculated to assess the performance of the proposed method. Moreover, the modeling procedures and characteristics of three different models in EEMF analysis were discussed and compared.
More Related Videos
08:26Analyzing the Interaction of Fluorescent-Labeled Proteins with Artificial Phospholipid Microvesicles using Quantitative Flow Cytometry
Published on: April 6, 2022
09:19In Vitro Microfluidic Disease Model to Study Whole Blood-Endothelial Interactions and Blood Clot Dynamics in Real-Time
Published on: May 24, 2020
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.