Related Experiment Video
Updated: Dec 5, 2025

Particle Image Velocimetry Investigation of Hemodynamics via Aortic Phantom
Published on: February 25, 2022
Cerebral Blood Flow in Patients with Severe Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Implantation
Wieneke Vlastra1, Astrid C van Nieuwkerk1, Anne-Sophie G T Bronzwaer2,3
1Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Heart Center, Amsterdam, the Netherlands.
Background:
Transcatheter aortic valve implantation (TAVI) is a minimally invasive, life-saving treatment for patients with severe aortic valve stenosis that improves quality of life. We examined cardiac output and cerebral blood flow in patients undergoing TAVI to test the hypothesis that improved cardiac output after TAVI is associated with an increase in cerebral blood flow.
Design:
Prospective cohort study.
Setting:
European high-volume tertiary multidisciplinary cardiac care.
Participants:
Thirty-one patients (78.3 ± 4.6 years; 61% female) with severe symptomatic aortic valve stenosis.
Measurements:
Noninvasive prospective assessment of cardiac output (L/min) by inert gas rebreathing and cerebral blood flow of the total gray matter (mL/100 g per min) using arterial spin labeling magnetic resonance imaging in resting state less than 24 hours before TAVI and at 3-month follow-up. Cerebral blood flow change was defined as the difference relative to baseline.
Results:
On average, cardiac output in patients with severe aortic valve stenosis increased from 4.0 ± 1.1 to 5.4 ± 2.4 L/min after TAVI (P = .003). The increase in cerebral blood flow after TAVI strongly varied between patients (7% ± 24%; P = .41) and related to the increase in cardiac output, with an 8.2% (standard error = 2.3%; P = .003) increase in cerebral blood flow per every additional liter of cardiac output following the TAVI procedure.
Conclusion:
Following TAVI, there was an association of increase in cardiac output with increase in cerebral blood flow. These findings encourage future larger studies to determine the influence of TAVI on cerebral blood flow and cognitive function.