Comparison of iohexol plasma clearance formulas vs. inulin urinary clearance for measuring glomerular filtration rate
Laurence Dubourg1,2,3, Sandrine Lemoine1,2,4, Brune Joannard1
1Néphrologie, Dialyse, Hypertension et Exploration Fonctionnelle Rénale, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France.
Objectives:
The one-compartment iohexol plasma clearance has been proposed as a reliable alternative to renal inulin clearance. However, this method's performance depends on the formula used to calculate glomerular filtration rate (GFR). This study reports on performance comparisons between various mathematical formulas proposed for iohexol plasma clearance vs. inulin urinary clearance.
Methods:
GFR was simultaneously determined by inulin and iohexol clearance in 144 participants (age: 10-84 years; glomerular filtration rate: 15-169 mL/min/1.73 m2). A retrospective cross-sectional study evaluated the performance of four formulas proposed to calculate plasma iohexol clearance (Brøchner-Mortensen, Fleming et al., Jødal-Brøchner-Mortensen, and Ng-Schwartz-Munoz). The performance of each formula was assessed using bias, precision (standard deviation of the bias), accuracy (percentage iohexol within 5, 10, and 15%), root mean square error, and concordance correlation coefficient vs. renal inulin clearance as reference.
Results:
Regarding accuracy, there was no difference in root mean square error (RMSE), P5, P10, or P15 between the four formulas. The four concordance correlation coefficients (CCC) between the value from each formula and in-GFR were high and not significantly different. At in-GFR ≥90 mL/min/1.73 m2, Ng-Schwartz-Munoz formula performed slightly better than other formulas regarding median bias (-0.5; 95% CI [-3.0 to 2.0] and accuracy P15 (95.0; 95% CI [88.0-100.0]).
Conclusions:
The studied formulas were found equivalent in terms of precision and accuracy, but the Ng-Schwartz-Munoz formula improved the accuracy at higher levels of in-GFR.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...