Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

A program system for interactive measurements on digitized cell images.

J Holmquist, E Bengtsson, O Eriksson

    The Journal of Histochemistry and Cytochemistry : Official Journal of the Histochemistry Society
    |July 1, 1977
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The novel collagen matrikine, endotrophin, is associated with mortality and cardiovascular events in patients with atherosclerosis.

    Journal of internal medicine·2021
    Same author

    Activation of immune responses against the basement membrane component collagen type IV does not affect the development of atherosclerosis in ApoE-deficient mice.

    Scientific reports·2019
    Same author

    A biomarker of collagen type I degradation is associated with cardiovascular events and mortality in patients with atherosclerosis.

    Journal of internal medicine·2018
    Same author

    Autoantibodies against aldehyde-modified collagen type IV are associated with risk of development of myocardial infarction.

    Journal of internal medicine·2017
    Same author

    Plasma stem cell factor levels are associated with risk of cardiovascular disease and death.

    Journal of internal medicine·2017
    Same author

    Human Lipoproteins at Model Cell Membranes: Effect of Lipoprotein Class on Lipid Exchange.

    Scientific reports·2017
    Same journal

    Expression and Spatial Localization of Glycosaminoglycan Types in Cartilage From Different Anatomical Locations.

    The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society·2026
    Same journal

    Aquaporin-4 Localization in Terminal Glial Cells of Human Mechanosensory Corpuscles: An Immunohistochemical Study of Penile Tissues.

    The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society·2026
    Same journal

    Seeing, Interpreting, and Trusting Images in the Age of Artificial Intelligence.

    The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society·2026
    Same journal

    P63 and Tight Junctions Targeted for Therapy in Human Salivary Duct Adenocarcinoma Cells.

    The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society·2026
    Same journal

    Human iPSC-Derived Blood Vessel Organoids for Studying Chronic Hypoxia-Induced Microvascular Dysfunction.

    The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society·2026
    Same journal

    From Manual to Macro: A Reproducible Fiji Workflow for Semi-automated Collagen Fibril Diameter Quantification in Transmission Electron Microscopy.

    The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society·2026
    See all related articles

    This study introduces an interactive system for analyzing microscopic images using a scanner and minicomputer. It enables precise object measurement and statistical analysis, enhancing research capabilities in microscopy.

    Area of Science:

    • Microscopy
    • Image Analysis
    • Computer Graphics

    Background:

    • Microscopic image analysis often requires specialized tools for precise measurements.
    • Interactive control over image processing enhances accuracy and flexibility.

    Purpose of the Study:

    • To develop a program system for interactive measurements on digitized microscopic images.
    • To enable operators to isolate objects and calculate various parameters under direct control.

    Main Methods:

    • Utilized a high-precision image scanner and a PDP-8/F minicomputer.
    • Developed an interactive system with a Tektronix 4010 graphic terminal for user interface.
    • Implemented a command scanner, parser, and interpreter for system control.

    Main Results:

    Related Experiment Videos

    • The system allows for interactive isolation of objects within microscopic images.
    • Calculated parameters include shape, light transmission irregularity, area, and integrated light transmission.
    • Stored data facilitates subsequent statistical analysis.

    Conclusions:

    • The developed system provides an effective interactive method for microscopic image analysis.
    • Its modular design allows for easy addition of new commands, enhancing versatility.